Tenant obtains water meter details

https://api.sciener.com/v3/waterMeterUser/detail

This interface doesn't require accessToken

1 Request example

POST, ContentType:application/x-www-form-urlencoded

2 Request parameters

NameTypeRequiredDescription
clientIdStringYAssigned client_id from created application
dateLongYCurrent time (timestamp, in milliseconds)
macStringYWater Meter MAC

3 Response and example

NameTypeDescription
waterMeterIdIntWater meter ID
nameStringWater meter name
numberStringWater meter number
macStringWater meter MAC
featureValueStringFeature value
modelNumStringProduct Model
hardwareRevisionStringHardware version number
firmwareRevisionStringFirmware version number
payModeIntOperating modes: 0 - Energy metering mode; 1 - Prepaid mode
syncM3DateStringMeter reading time
onlineIntOnline status: 0 - No 1 - Yes
rssiIntSignal strength
onOffIntWater flow status
totalM3StringTotal water consumption
remainderM3StringRemaining water volume
priceStringUnit price
executeTokenStringIf the token used during the recharge is not empty, it indicates that there are pending tasks.